Incoming Inspection for Electric Linear Actuators: A Checklist
Incoming inspection is the cheapest quality gate you have. Most field failures — a few millimetres of missing stroke, a louder gearbox, a current draw that creeps up — are visible at goods-in. Finding them after the unit is built into a machine costs several times more.
1. Match the paperwork
Check the nameplate against the order: model, voltage, stroke, force, speed, ingress rating and serial number. A revised gear ratio or limit style can hide behind an unchanged model code, so ask for the inspection record and wiring diagram with each lot, and confirm wire colours match the drawing.
2. Visual and mechanical checks
Look for dents, coating damage and rust. The rod must be free of scratches and pitting; a scored rod acts like sandpaper on the seal lip and lets water in within a few thousand cycles. Rest the actuator on a flat plate and check that both mounting eyes are square. Push and pull the rod by hand: resistance should be even, with no binding or tight spots, and no noticeable side play.
3. Stroke and limits
Measure fully retracted and fully extended length before applying power. Jog to both ends at low speed and watch the limit behaviour: an internal limit should cut out just before the mechanical stop, not against it. Run three full cycles and check that stroke does not drift and that the unit does not bump and stop, which means the limit is set late.
4. No-load current
No-load current is the highest-value check in the whole inspection. With a DC clamp meter, run the full stroke at rated voltage and record the inrush peak and the steady-state value. Expect a flat trace; a small rise near each end is normal, but not more than twice the steady value. Across a batch, units should sit within about plus or minus 15 percent. High current usually means thick grease, over-preload or motor variance; a fluctuating trace points to debris on the screw or a mis-pressed bearing. Keep both no-load and loaded figures in the machine file so later drift is measurable.
5. Noise and smoothness
Listen in a quiet area. A healthy unit gives a steady motor hum with light screw noise. A periodic knock suggests gear or bearing damage; a dry rasp suggests insufficient screw grease. A phone sound-level app is enough for relative comparison: measure several units at the same distance and reject anything more than 5 dB above the batch. Feel the housing too; noticeable buzz means balance or assembly problems.
6. Load and protection
Where possible, run at half rated load and check that speed drop and motor temperature are reasonable. On units with encoder or position feedback, confirm the signal tracks actual position over the full stroke without losing counts. On controllers with over-current protection, force one stall and confirm it trips within the set time rather than cooking the motor.
7. Sampling and rejects
For a first lot, inspect every unit for appearance and no-load current, then move to ten percent sampling, with full inspection on critical stations. Quarantine the whole batch on a failure, record lot and serial numbers, group by symptom, then talk to the supplier: a single bad unit is usually transport damage, a consistent offset across the batch is a process problem. LOUIE Electric Linear Actuator records full-stroke and no-load current data before dispatch, and Changzhou Louis Electric Push Rod can supply per-unit test records for incoming inspection.