Speed Control for Electric Linear Actuators: PWM, Soft Start and Multi-Speed
An actuator that races when unloaded and crawls under load, or slams into position and shakes the whole frame, is usually not a motor fault. Speed depends on the power supply, the controller, the screw lead and the inertia of the machine. This guide covers the practical ways to set and control speed on an electric linear actuator.
1. Where speed comes from
Linear speed equals motor rpm divided by the gear ratio, multiplied by screw lead. A larger lead or higher rpm gives a faster stroke; a small lead with a big reduction gives slow, strong motion. Specify both free-run speed and speed at rated load - they differ, especially on battery power where voltage sags under current.
2. Voltage reduction
Dropping 24 V to 18 V slows the actuator with almost no extra hardware. The trade-offs are higher current, more heat at low speed under load, and reduced thrust. It suits short duty and light loads, not continuous slow running.
3. PWM control
Pulse-width modulation switches the supply rapidly to vary average voltage, so losses and heat stay low. It is the mainstream method for actuator speed control. Too low a frequency produces audible whine and rough motion; too high adds switching loss and EMI. A few kilohertz to about twenty kilohertz is the usual band, chosen with the driver and cable length. Ramping duty from 30% to 100% feels far smoother than switching straight to full supply. With a Hall sensor or encoder, closed-loop control holds speed steady as the load changes.
4. Soft start and soft stop
Many speed complaints are really start and stop complaints. Inrush current can be several times rated, hammering the mechanics and rocking the load. Ramping duty over 0.3 to 1 second, and easing down at the end, cuts noise and structural stress. For desks, nursing beds and tilting mechanisms, soft ramps help more than a lower top speed.
5. Multi-speed operation
Most machines want two speeds: fast travel to save time, slow approach near the workpiece or the end stop. Either the controller outputs a different duty cycle, or a two-speed motor is switched. Pair the changeover with a limit switch or position feedback, otherwise the slow section starts at the wrong place. Under PLC control, keep the speeds as register parameters so they can be tuned on site.
6. Mechanical changes
If the whole machine is too slow, a larger screw lead beats raising voltage. If it must move slowly and hold position, a small-lead trapezoidal screw with self-locking is better - it will not back-drive when power is cut. Recalculate thrust and life, but the control logic stays simple and reliable.
7. Commissioning checklist
Measure no-load and full-load current to confirm supply headroom; check the PWM waveform on a scope; listen for whine at low speed; run ten minutes and feel the housing temperature; watch the frame during start and stop. Fix power and cabling before blaming the actuator. LOUIE Electric Linear Actuator supplies recommended duty and ramp settings for the required stroke time, so the machine does not need repeated trial and error on site.
8. Conclusion
There is no single answer to speed control: voltage adjustment for light short duty, PWM for continuous running, soft ramps where inertia is high, extra gears for multiple conditions, and a return to lead and ratio when the whole machine is mismatched. Calculate speed, thrust and duty together and keep a margin. Changzhou LOUIE Electric Linear Actuator recommends recording the speed curve on the prototype and reproducing the same parameters in production.